Detector Assemblies

Showing all 6 results

  • ElpasoLight CLYC nEL-38x38-R6231 scintillation detector

    ElpasoLight nEL-51×51-R6231

    Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm  (Ø2”x2”) high-performance ElpasoLight crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)

    Detector type Cs2LiYCl6
    Detector size Ø50.8×50.8 mm
    Energy range From 10 keV
    Typical resolution 4.5% at 662 keV
    Ambient dose rate N/A
    Typical sensitivity,
    cps/(µSv·h-1)
    1300(137Cs)
    Neutron detection Yes
    Readout  PMT+JEDEC B14-38
    Dimensions Ø60×167 mm
    Weight 700g
    Request a quote
  • ElpasoLight CLYC nEL-38x38-R6231 scintillation detector

    ElpasoLight nEL-38×38-R6231

    Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-38×38-R6231 Scintillation Detector Assembly includes Ø38.1×38.1 mm  (Ø1.5”x1.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional).

    Detector type Cs2LiYCl6
    Detector size Ø38.1×38.1 mm
    Energy range From 10 keV
    Typical resolution 4% at 662 keV
    Ambient dose rate N/A
    Typical sensitivity,
    cps/(µSv·h-1)
    600 (137Cs)
    Neutron detection Yes
    Readout  PMT+JEDEC B14-38
    Dimensions Ø60×156 mm
    Weight 470 g
    Request a quote
  • ElpasoLight CLYC nEL-51x102-R6231 scintillation detector

    ElpasoLight nEL-51×102-R6231

    Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×102-R6231 Scintillation Detector Assembly includes Ø50.8×101.6 mm (Ø2”x4”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).

    Detector type Cs2LiYCl6
    Detector size Ø50.8×101.6 mm
    Energy range From 10 keV
    Typical resolution 4.5% at 662 keV
    Ambient dose rate N/A
    Typical sensitivity,
    cps/(µSv·h-1)
    2600 (137Cs)
    2100 (60Co)
    Neutron detection Yes
    Readout  PMT+JEDEC B14-38
    Dimensions Ø60×218 mm
    Weight 870 g
    Request a quote

    Available on backorder

  • ElpasoLight nEL-63×63-R6232

    Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm  (Ø2.5”x2.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).

    Detector type Cs2LiYCl6
    Detector size Ø63.5×63.5 mm
    Energy range From 10 keV
    Typical resolution 4.5% at 662 keV
    Ambient dose rate N/A
    Typical sensitivity,
    cps/(µSv·h-1)
    2200 (137Cs)
    1870 (60Co)
    Neutron detection Yes
    Readout  PMT+JEDEC B14-38
    Dimensions Ø70×198 mm
    Weight 880 g
    Request a quote

    Available on backorder

  • ElpasoLight nEL-6x25c-SiPM

    Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-6x25c-SiPM Scintillation Detector Assembly includes 6x6x25 mm high-performance ElpasoLight crystal coupled to MicroFJ SiPM

    Detector type Cs2LiYCl6
    Detector size 6x6x25 mm
    Energy range From 10 keV
    Typical resolution 5% at 662 keV
    Ambient dose rate N/A
    Typical sensitivity,
    cps/(µSv·h-1)
    16 (137Cs)
    Neutron detection Yes
    Readout SiPM
    Dimensions 9x9x35 mm
    Weight 7 g
    Request a quote

    8 in stock (can be backordered)

  • ScintiClear SrI2(Eu) MacroPixel SC-14x25c-SiPM-T scintillation detector

    MacroPixel nEL-14x25c-SiPM-T

    Dual-mode neutron-gamma natural (7%) 6Li enriched nEl-14x25c Scintillation Detector Assembly includes 14x14x25.4 mm high-performance ElpasoLight crystal coupled to MicroFJ SiPM array with T-sensor

    Detector type Cs2LiYCl6
    Detector size 14x14x25.4 mm
    Energy range From 10 keV
    Typical resolution 5% at 662 keV
    Ambient dose rate N/A
    Typical sensitivity,
    cps/(µSv·h-1)
    90 (137Cs)
    Neutron detection Yes
    Readout SiPM
    Dimensions 17x17x32 mm
    Weight 25 g
    Request a quote