Detector Assemblies
Showing all 6 results
-
ElpasoLight nEL-51×51-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) high-performance ElpasoLight crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type Cs2LiYCl6 Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1300(137Cs) Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 700g -
ElpasoLight nEL-38×38-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-38×38-R6231 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)600 (137Cs) Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 470 g -
ElpasoLight nEL-51×102-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×102-R6231 Scintillation Detector Assembly includes Ø50.8×101.6 mm (Ø2”x4”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø50.8×101.6 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2600 (137Cs)
2100 (60Co)Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×218 mm Weight 870 g -
ElpasoLight nEL-63×63-R6232
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2200 (137Cs)
1870 (60Co)Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 880 g -
ElpasoLight nEL-6x25c-SiPM
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-6x25c-SiPM Scintillation Detector Assembly includes 6x6x25 mm high-performance ElpasoLight crystal coupled to MicroFJ SiPM
Detector type Cs2LiYCl6 Detector size 6x6x25 mm Energy range From 10 keV Typical resolution 5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)16 (137Cs) Neutron detection Yes Readout SiPM Dimensions 9x9x35 mm Weight 7 g -
MacroPixel nEL-14x25c-SiPM-T
Dual-mode neutron-gamma natural (7%) 6Li enriched nEl-14x25c Scintillation Detector Assembly includes 14x14x25.4 mm high-performance ElpasoLight crystal coupled to MicroFJ SiPM array with T-sensor
Detector type Cs2LiYCl6 Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)90 (137Cs) Neutron detection Yes Readout SiPM Dimensions 17x17x32 mm Weight 25 g