Products
Scintillation Probe SC-MacroPixel-MCA
MacroPixel LB-14x25c-SiPM-T Scintillation Detector Assembly includes 14x14x25.4 mm high-performance Lanthanum Bromide LaBr3(Ce,Sr) crystal coupled to MicroFJ SiPM array with T-sensor hermetically packed in an Aluminum housing with 0.5mm thick walls
Detector type | LaBr3(Ce) |
Detector size | 14x14x25.4 mm |
Energy range | From 10 keV |
Typical resolution | 3.0% at 662 keV |
Ambient dose rate | N/A |
Typical sensitivity, cps/(µSv·h-1) |
140 (137Cs) |
Neutron detection | None |
Readout | SiPM |
Dimensions | 17x17x32 mm |
Weight | 35 g |
The calculations are based on NIST XCOM: Photon Cross Sections Database. The results are for general information purpose only. You should not rely upon them as a basis for making any decisions.
Showing all 76 results
-
MacroPixel LB-14x25c-SiPM-T
MacroPixel LB-14x25c-SiPM-T Scintillation Detector Assembly includes 14x14x25.4 mm high-performance Lanthanum Bromide LaBr3(Ce,Sr) crystal coupled to MicroFJ SiPM array with T-sensor hermetically packed in an Aluminum housing with 0.5mm thick walls
Detector type LaBr3(Ce) Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)140 (137Cs) Neutron detection None Readout SiPM Dimensions 17x17x32 mm Weight 35 g -
Scintillation Probe SC-MacroPixel-MCA
SC-MacroPixel-MCA Scintillation Gamma Radiation Probe includes 14x14x25.4 mm high-performance ScintiClear SrI2(Eu) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI.
Detector type / size SrI2(Eu) / 14x14x25.4 mm Energy range 10 – 4000 keV Typical resolution 3.0% at 662 keV Maximum count rate, cps 25000 Typical sensitivity,
cps/(µSv·h-1)130 (137Cs) Protection class IP67 Interface Micro USB Type B Operation temperature -40°C to +50°C Dimensions / weight 17x17x70 mm / 40 g -
MacroPixel SC-14x25c-SiPM-T
MacroPixel SC-14x25c-SiPM-T Scintillation Detector Assembly includes 14x14x25.4 mm high-performance ScintiClear SrI2(Eu) crystal coupled to MicroFJ SiPM array with T-sensor. Europium-doped strontium iodide (SrI2:Eu) is a recently developed halide scintillator that supersedes older detector materials due to its ruggedness, radiation hardness, absence of internal activity, high sensitivity, lower cost, excellent linearity, and high energy resolution over a wide energy range, from a few keV to tens of MeV.
Detector type SrI2(Eu) Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)130 (137Cs) Neutron detection No Readout SiPM Dimensions 17x17x32 mm Weight 32 g -
ElpasoLight nEL-51×51-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) high-performance ElpasoLight crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type Cs2LiYCl6 Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1300(137Cs) Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 700g -
Array16-ScintiClear-MacroPixel
MacroPixel SC-14x25c Scintillation Detector Assembly includes 14x14x25.4 mm high-performance ScintiClear SrI2(Eu) crystal coupled to SiPM array with T-sensor
Detector type SrI2(Eu) Detector size 14x14x25.4 mm (16 pcs) Energy range From 10 keV Typical pixel resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1600 (137Cs)
1250 (60Co)Neutron detection No Readout SiPM Dimensions 67x67x38 mm Weight 450 g -
Detector Assembly CsI-38×38-R6231
CsI-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) CsI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type CsI(Tl) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)800 (137Cs)
400 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 530 g -
Detector Assembly CsI-51×51-R6231
CsI-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) CsI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type CsI(Tl) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 5.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1500 (137Cs)
1200 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 850 g -
Detector Assembly CsI-63×63-R6232
CsI-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) CsI(Tl) crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type CsI(Tl) Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2500 (137Cs)
2150 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 1140 g -
Detector Assembly LB-20x38c-SiPM-T
LB-20x38c-SiPM-T Scintillation Detector Assembly includes 20x20x38.1 mm high-performance Lanthanum Bromide LaBr3(Ce) crystal coupled to MicroFJ SiPM array with T-sensor hermetically packed in an Aluminum housing with 0.5mm thick walls
Detector type LaBr3(Ce) Detector size 20x20x38.1 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)350 (137Cs) Neutron detection None Readout SiPM Dimensions 23x23x52 mm Weight 95 g -
Detector Assembly LB-38×38-R6231
LB-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance Lanthanum Bromide LaBr3(Ce) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type LaBr3(Ce) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)850 (137Cs)
630 (60Co)Neutron detection None Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 600 g -
Detector Assembly NaI-38×38-R6231
NaI-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) NaI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type NaI(Tl) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)650 (137Cs) Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 480 g -
Detector Assembly NaI-51×51-R6231
NaI-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) NaI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type NaI(Tl) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1350 (137Cs) Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 750 g -
Detector Assembly NaI-63×63-R6232
NaI-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) NaI(Tl) crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type NaI(Tl) Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2300 (137Cs)
1970 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 900 g -
ElpasoLight nEL-38×38-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-38×38-R6231 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)600 (137Cs) Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 470 g -
ElpasoLight nEL-51×102-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×102-R6231 Scintillation Detector Assembly includes Ø50.8×101.6 mm (Ø2”x4”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø50.8×101.6 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2600 (137Cs)
2100 (60Co)Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×218 mm Weight 870 g -
ElpasoLight nEL-63×63-R6232
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2200 (137Cs)
1870 (60Co)Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 880 g -
ElpasoLight nEL-6x25c-SiPM
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-6x25c-SiPM Scintillation Detector Assembly includes 6x6x25 mm high-performance ElpasoLight crystal coupled to MicroFJ SiPM
Detector type Cs2LiYCl6 Detector size 6x6x25 mm Energy range From 10 keV Typical resolution 5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)16 (137Cs) Neutron detection Yes Readout SiPM Dimensions 9x9x35 mm Weight 7 g -
MacroPixel CHC-14x25c-SiPM-T
MacroPixel CHC-14x25c-SiPM-T Scintillation Detector Assembly includes 14x14x25.4 mm high-performance Cs2HfCl6 (CHC) crystal couplet to SiPM array with T-sensor
Detector type Cs2HfCl6 Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)130 (137Cs) Neutron detection No Readout SiPM Dimensions 17x17x32 mm Weight 32 g -
MacroPixel CsI-14x25c-SiPM-T
CsI-14x25c Scintillation Detector Assembly includes 14x14x25.4 mm CsI(Tl) crystal coupled to MicroFJ SiPM array with T-sensor
Detector type CsI(Tl) Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)120 (137Cs) Neutron detection No Readout SiPM Dimensions 17x17x32 mm Weight 32 g -
MacroPixel NaI-14x25c-SiPM-T
NaI-14x25c Scintillation Detector Assembly includes 14x14x25.4 mm NaI(Tl) crystal coupled to MicroFJ SiPM array with T-sensor
Detector type NaI(Tl) Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)95 (137Cs) Neutron detection No Readout SiPM Dimensions 17x17x32 mm Weight 25 g -
MacroPixel nEL-14x25c-SiPM-T
Dual-mode neutron-gamma natural (7%) 6Li enriched nEl-14x25c Scintillation Detector Assembly includes 14x14x25.4 mm high-performance ElpasoLight crystal coupled to MicroFJ SiPM array with T-sensor
Detector type Cs2LiYCl6 Detector size 14x14x25.4 mm Energy range From 10 keV Typical resolution 5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)90 (137Cs) Neutron detection Yes Readout SiPM Dimensions 17x17x32 mm Weight 25 g -
MegaPixel CsI-28x51c-SiPM-T
MegaPixel CsI-28x51c Scintillation Detector Assembly includes 28x28x50.8 mm CsI(Tl) crystal coupled to SiPM array with T-sensor
Detector type CsI(Tl) Detector size 28x28x50.8 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)780 (137Cs)
590 (60Co)Neutron detection No Readout SiPM Dimensions 31x31x64 mm Weight 200 g -
MegaPixel NaI-28x51c-SiPM-T
MegaPixel NaI-28x51c Scintillation Detector Assembly includes 28x28x50.8 mm NaI(Tl) crystal coupled to SiPM array with T-sensor
Detector type NaI(Tl) Detector size 28x28x50.8 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)690 (137Cs)
515 (60Co)Neutron detection No Readout SiPM Dimensions 31x31x64 mm Weight 165 g -
MegaPixel SC-28x51c-SiPM-T
MegaPixel SC-28x51c-SiPM-T Scintillation Detector Assembly includes 28x28x50.8mm high-performance ScintiClear SrI2(Eu) crystal coupled to MicroFJ SiPM array with T-sensor. Europium-doped strontium iodide (SrI2:Eu) is a recently developed halide scintillator that supersedes older detector materials due to its ruggedness, radiation hardness, absence of internal activity, high sensitivity, lower cost, excellent linearity, and high energy resolution over a wide energy range, from a few keV to tens of MeV.
Detector type SrI2(Eu) Detector size 28x28x50.8 mm Energy range From 10 keV Typical resolution 3.2% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)780 (137Cs)
600 (60Co)Neutron detection No Readout SiPM Dimensions 31x31x64 mm Weight 200 g -
ScintiClear SC-14x1c-SiPM-T
SC-14x1c Scintillation Detector Assembly includes 14x14x1 mm high-performance ScintiClear crystal with 0.1 mm Be window for low energy X-rays, and coupled to MicroFJ SiPM array with T-sensor
Detector type SrI2(Eu) Detector size 14x14x1 mm Energy range From 2 keV Typical resolution 6% at 122 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)N/A Neutron detection No Readout SiPM Dimensions 17x17x18 mm Weight 8 g -
ScintiClear SC-38×38-R6231
SC-38×38-R6231 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance ScintiClear SrI2(Eu) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector Type SrI2(Eu) Detector Size Ø38.1×38.1 mm Energy Range From 10 keV Typical Resolution 3.0% at 662 keV Ambient Dose Rate N/A Typical Sensitivity,
cps/(µSv·h-1)800 (137Cs)
600 (60Co)Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 530 g -
ScintiClear SC-38×38-R6231-01
SC-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance ScintiClear crystal coupled to Hamamatsu R6231-100-01 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector Type SrI2(Eu) Detector Size Ø38.1×38.1 mm Energy Range From 10 keV Typical Resolution 3.0% at 662 keV Ambient Dose Rate N/A Typical Sensitivity,
cps/(µSv·h-1)800 (137Cs)
400 (60Co)Readout PMT Dimensions Ø60×150 mm Weight 530 g -
ScintiClear SC-46×46-R6231
SC-46×46 Scintillation Detector Assembly includes Ø46.0×46.0 mm high-performance ScintiClear crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type SrI2(Eu) Detector size Ø46.0×46.0 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1150 (137Cs)
970 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×164 mm Weight 710 g -
ScintiClear SC-51×25-R6232
SC-51×25 Scintillation Detector Assembly includes Ø50.8×25.4 mm (Ø2”x1”) high-performance ScintiClear crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type SrI2(Eu) Detector size Ø50.8×25.4 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1050 (137Cs)
800 (60Co)Readout PMT+JEDEC B14-38 Dimensions Ø70×160 mm Weight 570 g -
ScintiClear SC-51×51-R6232
SC-51×51-R6232 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) high-performance ScintiClear SrI2(Eu) crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls, integrated magnetic shield and temperature sensor (optional)
Detector type SrI2(Eu) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1500 (137Cs)
1200 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø70×190 mm Weight 850 g -
ScintiClear SC-6x25c-SiPM
SC-6x25c-SiPM Scintillation Detector Assembly includes 6x6x25 mm high-performance ScintiClear crystal coupled to MicroFJ SiPM
Detector type SrI2(Eu) Detector size 6x6x25 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)20 (137Cs) Neutron detection No Readout SiPM Dimensions 9x9x35 mm Weight 8 g -
ScintiClear SC-6x6c-SiPM
SC-6x6c-SiPM Scintillation Detector Assembly includes 6x6x6 mm high-performance ScintiClear crystal coupled to MicroFJ SiPM
Detector type SrI2(Eu) Detector size 6x6x6 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)5 (137Cs) Neutron detection No Readout SiPM Dimensions 9x9x16 mm Weight 3 g -
Scintillation Crystal CHC-13c
Cs2HfCl6 scintillation crystal 12.7×12.7×12.7 mm hermetically packed in an Aluminum housing with 0.5 mm thick walls and 12.7×12.7 mm fused silica window
Detector type Cs2HfCl6 Detector size 12.7×12.7×12.7 mm Energy range From 10 keV Typical resolution 3.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)70 (137Cs) Neutron detection None Dimensions 16x16x16 mm Weight 13 g -
Scintillation Crystal CHC-25×25
Cs2HfCl6 scintillation crystal Ø25.4×25.4 mm (Ø1”x1”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type Cs2HfCl6 Detector size Ø25.4×25.4 mm Energy range From 15 keV Typical resolution 4.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)260 (137Cs) Neutron detection None Dimensions Ø32×32 mm Weight 80 g -
Scintillation Crystal CsI-12x12x40
Unpacked CsI(Tl) scintillation crystal 12x12x40 mm with one end chamfered. Available with all sides polished or fine grinded.
Detector type CsI(Tl) Detector size 12x12x40 mm Energy range From 2 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)100 (137Cs)
75 (60Co)Neutron detection No Dimensions 12x12x40 mm Weight 28 g -
Scintillation Crystal CsI-25×25
CsI(Tl) scintillation crystal Ø25.4×25.4 mm (Ø1”x1”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type CsI(Tl) Detector size Ø25.4×25.4 mm Energy range From 15 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)260 (137Cs) Neutron detection None Dimensions Ø32×32 mm Weight 80 g -
Scintillation Crystal CsI-38×38
CsI(Tl) scintillation crystal Ø38.1×38.1 mm (Ø1.5”x1.5”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type CsI(Tl) Detector size Ø38.1×38.1 mm Energy range From 15 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)750 (137Cs)
590 (60Co)Neutron detection No Dimensions Ø46×46 mm Weight 240 g -
Scintillation Crystal CsI-40×40
CsI(Tl) scintillation crystal Ø40.0×40.0 mm hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type CsI(Tl) Detector size Ø40.0×40.0 mm Energy range From 15 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)850 (137Cs)
670 (60Co)Neutron detection No Dimensions Ø46×46 mm Weight 275 g -
Scintillation Crystal CsI-51×51
CsI(Tl) scintillation crystal Ø50.8×50.8 mm (Ø2”x2”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø57 mm fused silica window
Detector type CsI(Tl) Detector size Ø50.8×50.8 mm Energy range From 15 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1500 (137Cs)
1200 (60Co)Neutron detection No Dimensions Ø59×58 mm Weight 580 g -
Scintillation Crystal CsI-63×63-G
CsI(Tl) scintillation crystal Ø63.5×63.5 mm (Ø2.5”x2.5”) hermetically packed in an Aluminum housing with 1.5 mm thick walls and Ø66 mm (Ø2.6”) fused silica window
Detector type CsI(Tl) Detector size Ø63.5×63.5 mm Energy range From 20 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2500 cps/(µSv·h-1) Neutron detection None Dimensions Ø71×72 mm Weight 1050 g -
Scintillation Crystal CsI-8x8x40
Unpacked CsI(Tl) scintillation crystal 8x8x40 mm with one end chamfered. Available with all sides polished or fine grinded.
Detector type CsI(Tl) Detector size 8x8x40 mm Energy range From 2 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)43 (137Cs)
35 (60Co)Neutron detection No Dimensions 8x8x40 mm Weight 12.5 g -
Scintillation Crystal LB-25×25
LaBr3(Ce) scintillation crystal Ø25.4×25.4 mm (Ø1”x1”) hermetically packed in an Aluminum housing with 1.0 mm thick walls and fused silica window
Detector type LaBr3(Ce) Detector size Ø25.4×25.4 mm Energy range From 15 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)275 (137Cs) Neutron detection None Dimensions Ø32×32 mm Weight 90 g -
Scintillation Crystal LB-38×38
Lanthanum Bromide LaBr3(Ce) scintillation crystal Ø38.1×38.1 mm (Ø1.5”x1.5”) hermetically packed in an Aluminum housing with 0.5 mm thick walls and fused silica window.
Detector type LaBr3(Ce) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)850 (137Cs)
630 (60Co)Neutron detection None Dimensions Ø46×46 mm Weight 280 g -
Scintillation Crystal LB-51×51
Lanthanum Bromide LaBr3(Ce) scintillation crystal Ø50.8×50.8 mm (Ø2”x2”) hermetically packed in an Aluminum housing with 0.5 mm thick walls and fused silica window
Detector type LaBr3(Ce) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1600 (137Cs)
1250 (60Co)Neutron detection None Dimensions Ø59×58 mm Weight 650 g -
Scintillation Crystal NaI-38×38
NaI(Tl) scintillation crystal Ø38.1×38.1 mm (Ø1.5”x1.5”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type NaI(Tl) Detector size Ø38.1×38.1 mm Energy range From 15 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)670 (137Cs) Neutron detection No Dimensions Ø46×46 mm Weight 210 g -
Scintillation Crystal NaI-40×40
NaI(Tl) scintillation crystal Ø40.0×40.0 mm hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type NaI(Tl) Detector size Ø40.0×40.0 mm Energy range From 15 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)750 (137Cs) Neutron detection No Dimensions Ø46×46 mm Weight 230 g -
Scintillation Crystal NaI-51×51
NaI(Tl) scintillation crystal Ø50.8×50.8 mm (Ø2”x2”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø57 mm fused silica window
Detector type NaI(Tl) Detector size Ø50.8×50.8 mm Energy range From 15 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1350 (137Cs) Neutron detection No Dimensions Ø59×58 mm Weight 490 g -
Scintillation Crystal NaI-76×76
NaI(Tl) scintillation crystal Ø76.2×76.2 mm (Ø3”x3”) hermetically packed in an Aluminum housing with 1.5 mm thick walls and Ø83 mm fused silica window
Detector type NaI(Tl) Detector size Ø76.2×76.2 mm Energy range From 15 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)3550 (137Cs) Neutron detection No Dimensions Ø86×84 mm Weight 1450 g -
Scintillation Crystal nEL-25×25
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø25.4×25.4 mm (Ø1”x1”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø25.4×25.4 mm Energy range From 15 keV Typical resolution 4.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)210 (137Cs) Neutron detection Yes Dimensions Ø32×32 mm Weight 65 g -
Scintillation Crystal nEL-25×38
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø25.4×38.1 mm (Ø1”x1.5”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø25.4×38.1 mm Energy range From 15 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)315 (137Cs) Neutron detection Yes Dimensions Ø32×45 mm Weight 90 g -
Scintillation Crystal nEL-38×38
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø38.1×38.1 mm (Ø1.5”x1.5”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø38.1×38.1 mm Energy range From 15 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)620 (137Cs) Neutron detection Yes Dimensions Ø46×46 mm Weight 190 g -
Scintillation Crystal nEL-40×40
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø40.0×40.0 mm hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø40.0×40.0 mm Energy range From 15 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)715 (137Cs) Neutron detection Yes Dimensions Ø46×46 mm Weight 210 g -
Scintillation Crystal nEL-51×102
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø50.8×101.6 mm (Ø2”x4”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø57 mm fused silica window.
Detector type Cs2LiYCl6 Detector size Ø50.8×101.6 mm Energy range From 15 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2600 (137Cs)
2100 (60Co)Neutron detection Yes Dimensions Ø59×110 mm Weight 900 g -
Scintillation Crystal nEL-51×51
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø50.8×50.8 mm (Ø2”x2”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø57 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø50.8×50.8 mm Energy range From 15 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1300 (137Cs) Neutron detection Yes Dimensions Ø59×58 mm Weight 450 g -
Scintillation Crystal nEL-51x51x13
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal 50.8×50.8×12.7 mm with optical window on the 50.8×50.8mm face
Detector type Cs2LiYCl6 Detector size 50.8×50.8×12.7 mm Energy range From 15 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)620 (137Cs) Neutron detection Yes Dimensions 56x56x19 mm Weight 155 g -
Scintillation Crystal nEl-63×63-G
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø63.5×63.5 mm (Ø2.5”x2.5”) hermetically packed in an Aluminum housing with 1.5mm thick walls and Ø66 mm (Ø2.6”) fused silica window
Detector type Cs2LiYCl6 Detector size Ø63.5×63.5 mm Energy range From 20 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2200 (137Cs) Neutron detection Yes Dimensions Ø71×72 mm Weight 780 g -
Scintillation Crystal nEL-76×152
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø76.2×152.4 mm (Ø3”x6”) hermetically packed in an Aluminum housing with 1.5 mm thick walls and Ø83 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø76.2×152.4 mm Energy range From 20 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)6900 (137Cs)
6000 (60Co)Neutron detection Yes Dimensions Ø86×165 mm Weight 2800 g -
Scintillation Crystal nEL-76×76
Dual-mode neutron-gamma natural (7%) 6Li enriched ElpasoLight™ CLYC scintillation crystal Ø76.2×76.2 mm (Ø3”x3”) hermetically packed in an Aluminum housing with 1.5 mm thick walls and Ø83 mm fused silica window
Detector type Cs2LiYCl6 Detector size Ø76.2×76.2 mm Energy range From 15 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)3450 (137Cs) Neutron detection Yes Dimensions Ø86×84 mm Weight 1300 g -
Scintillation Crystal SC-25×2
ScintiClear™ SrI2(Eu) scintillation crystal Ø25.4×2 mm with 0.1mm Be window for low energy X-rays
Detector type SrI2(Eu) Detector size Ø25.4×2 mm Energy range From 2 keV Typical resolution 30% at 5.9 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)N/A (137Cs)
N/A (60Co)Neutron detection None Dimensions Ø30×7 mm Weight 12 g -
Scintillation Probe CsI-MacroPixel-MCA
CsI-MacroPixel-MCA Scintillation Gamma Radiation Probe includes 14x14x25.4 mm CsI(Tl) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size CsI(Tl) / 14x14x25.4 mm Energy range 10 – 4000 keV Typical resolution 6% at 662 keV Maximum count rate, cps 40000 Typical sensitivity,
cps/(µSv·h-1)120 (137Cs) Neutron detection No Protection class IP67 Interface Micro USB Type B Operation temperature -20°C to +50°C Dimensions / weight 17x17x70 mm / 40 g -
Scintillation Probe CsI-MegaPixel-MCA
CsI-MegaPixel-MCA Scintillation Gamma Radiation Probe includes 28x28x50.8 mm CsI(Tl) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size CsI(Tl) / 28x28x50.8 mm Energy range 10 – 4000 keV Typical resolution 6.5% at 662 keV Maximum count rate, cps 40000 Typical sensitivity,
cps/(µSv·h-1)780 (137Cs)
590 (60Co)Neutron detection No Protection class IP67 Interface Micro USB Type B Operation temperature -20°C to +50°C Dimensions / weight 31x31x95 mm / 210 g -
Scintillation Probe LaBr-MegaPixel-MCA
SC-MegaPixel-MCA Scintillation Gamma Radiation Probe includes 28x28x50.8 mm high-performance ScintiClear SrI2(Eu) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size LaBr(Ce,Sr) / 28x28x50.8 mm Energy range 20 – 4000 keV Typical resolution 3.0% at 662 keV Maximum count rate, cps 100,000 Typical sensitivity,
cps/(µSv·h-1)810 (137Cs)
650 (60Co)Protection class IP67 Interface Micro USB Type B Operation temperature -20°C to +50°C Dimensions / weight 31x31x95 mm / 230 g -
Scintillation Probe NaI-MacroPixel-MCA
NaI-MacroPixel-MCA Scintillation Gamma Radiation Probe includes 14x14x25.4 mm NaI(Tl) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size NaI(Tl) / 14x14x25.4 mm Energy range 10 – 4000 keV Typical resolution 6.5% at 662 keV Maximum count rate, cps 50000 Typical sensitivity,
cps/(µSv·h-1)95 (137Cs) Neutron detection No Protection class IP67 Interface Micro USB Type B Operation temperature -40°C to +50°C Dimensions / weight 17x17x70 mm / 35 g -
Scintillation Probe NaI-MegaPixel-MCA
NaI-MegaPixel-MCA Scintillation Gamma Radiation Probe includes 28x28x50.8 mm NaI(Tl) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size NaI(Tl) / 28x28x50.8 mm Energy range 10 – 4000 keV Typical resolution 6.5% at 662 keV Maximum count rate, cps 50000 Typical sensitivity,
cps/(µSv·h-1)690 (137Cs)
515 (60Co)Neutron detection No Protection class IP67 Interface Micro USB Type B Operation temperature -20°C to +50°C Dimensions / weight 31x31x95 mm /175 g -
Scintillation Probe nEL-MacroPixel-MCA
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-MacroPixel-MCA Scintillation Probe includes 14x14x25.4 mm high-performance ElpasoLight coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, gamma-neutron discrimination, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size Cs2LiYCl6 / 14x14x25.4 mm Energy range 20 – 4000 keV Typical resolution 6% at 662 keV Maximum count rate, cps 20000 Typical sensitivity,
cps/(µSv·h-1)90 (137Cs) Neutron detection Yes Protection class IP67 Interface Micro USB Type B Operation temperature -40°C to +50°C Dimensions / weight 17x17x70 mm / 35 g -
Scintillation Probe SC-MegaPixel-MCA
SC-MegaPixel-MCA Scintillation Gamma Radiation Probe includes 28x28x50.8 mm high-performance ScintiClear SrI2(Eu) crystal coupled to SiPM array read by ultra-compact power over USB MCA with temperature stabilization, pulse pile-up rejection, and user-friendly GUI for Windows and Android
Detector type / size SrI2(Eu) / 28x28x50.8 mm Energy range 20 – 4000 keV Typical resolution 3.8% at 662 keV Maximum count rate, cps 20000 Typical sensitivity,
cps/(µSv·h-1)780 (137Cs)
600 (60Co)Protection class IP67 Interface Micro USB Type B Operation temperature -20°C to +50°C Dimensions / weight 31x31x95 mm / 210 g -
Scintillation Crystal SC-25×25
ScintiClear™ SrI2(Eu) scintillation crystal Ø25.4×25.4 mm (Ø1”x1”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type SrI2(Eu) Detector size Ø25.4×25.4 mm Energy range From 15 keV Typical resolution 3.2% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)260 (137Cs) Neutron detection No Dimensions Ø32×32 mm Weight 80 g -
Scintillation Crystal NaI-25×25
NaI(Tl) scintillation crystal Ø25.4×25.4 mm (Ø1”x1”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type NaI(Tl) Detector size Ø25.4×25.4 mm Energy range From 15 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)225 (137Cs) Neutron detection No Dimensions Ø32×32 mm Weight 70 g -
Scintillation Crystal SC-25×38
ScintiClear™ SrI2(Eu) scintillation crystal Ø25.4×38.1 mm (Ø1”x1.5”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø30 mm fused silica window
Detector type SrI2(Eu) Detector size Ø25.4×38.1 mm Energy range From 15 keV Typical resolution 3.2% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)390 (137Cs) Neutron detection No Dimensions Ø32×45 mm Weight 110 g -
Scintillation Crystal NaI-63×63-G
NaI(Tl) Scintillation Crystal Ø63.5×63.5 mm (Ø2.5”x2.5”) hermetically packed in an Aluminum housing with 1.5mm thick walls and Ø66 mm (Ø2.6”) fused silica window
Detector Type NaI(Tl) Detector Size Ø63.5×63.5 mm Energy Range From 20 keV Typical Resolution 6.5% at 662 keV Ambient Dose Rate N/A Typical Sensitivity,
cps/(µSv·h-1)2000 (137Cs) Neutron detection No Dimensions Ø71×72 mm Weight 840 g -
Scintillation Crystal SC-38×38
ScintiClear™ SrI2(Eu) scintillation crystal Ø38.1×38.1 mm (Ø1.5”x1.5”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type SrI2(Eu) Detector size Ø38.1×38.1 mm Energy range From 15 keV Typical resolution 3.2% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)750 (137Cs)
590 (60Co)Neutron detection No Dimensions Ø46×46 mm Weight 240 g -
Scintillation Crystal SC-40×40
ScintiClear™ SrI2(Eu) scintillation crystal Ø40.0×40.0 mm hermetically packed in an Aluminum housing with 1 mm thick walls and Ø44 mm fused silica window
Detector type SrI2(Eu) Detector size Ø40.0×40.0 mm Energy range From 15 keV Typical resolution 3.2% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)850 (137Cs)
670 (60Co)Neutron detection No Dimensions Ø46×46 mm Weight 275 g -
Scintillation Crystal SC-51×2
ScintiClear™ SrI2(Eu) scintillation crystal Ø50.8×2 mm with 0.1mm Be window for low energy X-rays
Detector type SrI2(Eu) Detector size Ø50.8×2 mm Energy range From 2 keV Typical resolution 30% at 5.9 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)N/A (137Cs)
N/A (60Co)Neutron detection None Dimensions Ø57×7 mm Weight 48 g -
Scintillation Crystal SC-51×51
ScintiClear™ SrI2(Eu) scintillation crystal Ø50.8×50.8 mm (Ø2”x2”) hermetically packed in an Aluminum housing with 1 mm thick walls and Ø57 mm fused silica window
Detector type SrI2(Eu) Detector size Ø50.8×50.8 mm Energy range From 15 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1500 (137Cs)
1200 (60Co)Neutron detection No Dimensions Ø59×58 mm Weight 580 g -
Scintillation Crystal SC-63×63-G
ScintiClear™ SrI2(Eu) scintillation crystal Ø63.5×63.5 mm (Ø2.5”x2.5”) hermetically packed in an Aluminum housing with 1.5 mm thick walls and Ø66 mm (Ø2.6”) fused silica window
Detector type SrI2(Eu) Detector size Ø63.5×63.5 mm Energy range From 15 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2500 (137Cs)
2150 (60Co)Neutron detection No Dimensions Ø71×72 mm Weight 1050 g -
Scintillation Crystal SC-76×76
ScintiClear™ SrI2(Eu) scintillation crystal Ø76.2×76.2 mm (Ø3”x3”) hermetically packed in an Aluminum housing with 1.5 mm thick walls and Ø83 mm fused silica window
Detector type SrI2(Eu) Detector size Ø76.2×76.2 mm Energy range From 15 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)3750 (137Cs)
3350 (60Co)Neutron detection No Dimensions Ø86×84 mm Weight 1750 g