Detector Assemblies
Showing all 15 results
-
ElpasoLight nEL-51×51-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) high-performance ElpasoLight crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type Cs2LiYCl6 Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1300(137Cs) Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 700g -
Detector Assembly CsI-38×38-R6231
CsI-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) CsI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type CsI(Tl) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)800 (137Cs)
400 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 530 g -
Detector Assembly CsI-51×51-R6231
CsI-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) CsI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type CsI(Tl) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 5.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1500 (137Cs)
1200 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 850 g -
Detector Assembly CsI-63×63-R6232
CsI-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) CsI(Tl) crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type CsI(Tl) Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 6% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2500 (137Cs)
2150 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 1140 g -
Detector Assembly LB-38×38-R6231
LB-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance Lanthanum Bromide LaBr3(Ce) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type LaBr3(Ce) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 3.0% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)850 (137Cs)
630 (60Co)Neutron detection None Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 600 g -
Detector Assembly NaI-38×38-R6231
NaI-38×38 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) NaI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type NaI(Tl) Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)650 (137Cs) Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 480 g -
Detector Assembly NaI-51×51-R6231
NaI-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) NaI(Tl) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type NaI(Tl) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1350 (137Cs) Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×167 mm Weight 750 g -
Detector Assembly NaI-63×63-R6232
NaI-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) NaI(Tl) crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type NaI(Tl) Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 6.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2300 (137Cs)
1970 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 900 g -
ElpasoLight nEL-38×38-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-38×38-R6231 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø38.1×38.1 mm Energy range From 10 keV Typical resolution 4% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)600 (137Cs) Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 470 g -
ElpasoLight nEL-51×102-R6231
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×102-R6231 Scintillation Detector Assembly includes Ø50.8×101.6 mm (Ø2”x4”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø50.8×101.6 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2600 (137Cs)
2100 (60Co)Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø60×218 mm Weight 870 g -
ElpasoLight nEL-63×63-R6232
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-63×63 Scintillation Detector Assembly includes Ø63.5×63.5 mm (Ø2.5”x2.5”) high-performance ElpasoLight CLYC crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional).
Detector type Cs2LiYCl6 Detector size Ø63.5×63.5 mm Energy range From 10 keV Typical resolution 4.5% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)2200 (137Cs)
1870 (60Co)Neutron detection Yes Readout PMT+JEDEC B14-38 Dimensions Ø70×198 mm Weight 880 g -
ScintiClear SC-38×38-R6231
SC-38×38-R6231 Scintillation Detector Assembly includes Ø38.1×38.1 mm (Ø1.5”x1.5”) high-performance ScintiClear SrI2(Eu) crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector Type SrI2(Eu) Detector Size Ø38.1×38.1 mm Energy Range From 10 keV Typical Resolution 3.0% at 662 keV Ambient Dose Rate N/A Typical Sensitivity,
cps/(µSv·h-1)800 (137Cs)
600 (60Co)Readout PMT+JEDEC B14-38 Dimensions Ø60×156 mm Weight 530 g -
ScintiClear SC-46×46-R6231
SC-46×46 Scintillation Detector Assembly includes Ø46.0×46.0 mm high-performance ScintiClear crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type SrI2(Eu) Detector size Ø46.0×46.0 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1150 (137Cs)
970 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø60×164 mm Weight 710 g -
ScintiClear SC-51×25-R6232
SC-51×25 Scintillation Detector Assembly includes Ø50.8×25.4 mm (Ø2”x1”) high-performance ScintiClear crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor (optional)
Detector type SrI2(Eu) Detector size Ø50.8×25.4 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1050 (137Cs)
800 (60Co)Readout PMT+JEDEC B14-38 Dimensions Ø70×160 mm Weight 570 g -
ScintiClear SC-51×51-R6232
SC-51×51-R6232 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) high-performance ScintiClear SrI2(Eu) crystal coupled to Hamamatsu R6232 PMT hermetically packed in an Aluminum housing with 0.5 mm thick walls, integrated magnetic shield and temperature sensor (optional)
Detector type SrI2(Eu) Detector size Ø50.8×50.8 mm Energy range From 10 keV Typical resolution 3% at 662 keV Ambient dose rate N/A Typical sensitivity,
cps/(µSv·h-1)1500 (137Cs)
1200 (60Co)Neutron detection No Readout PMT+JEDEC B14-38 Dimensions Ø70×190 mm Weight 850 g